One measurement problem,
three ways to buy it.

Every Tremon product is the same NDIR core at a different level of integration: the channel you build into your own instrument, the instrument you install in the field, or the system that collects, alarms and reports. Pick by the rule you have to satisfy — or by the gas.

ShareLinkedInEmailWhatsAppX
Start here

Which rule are you buying for?

Regulation → gas → product. Dates and obligations are explained on the Regulation → measurement page.

Regulation / obligationGasTremon product
F-gas · Reg. (EU) 2024/573
SF₆ switchgear leak-check exemption · room / leak monitoring
SF₆ · refrigerantsDM-91 density monitor with alert · IR·SF₆ transmitter · GDC-S52 multi-point sampling for GIS rooms · IR·OEM SF₆ channel
Methane · Reg. (EU) 2024/1787
LDAR surveys · continuous CH₄ monitoring · MRV
CH₄ (ppm → %LEL)TRM-EX-IR field analyzer (Ex) · IR·OEM CH₄ channel for survey instruments
Biomethane · REPowerEU 35 bcm
digester control · grid-injection gas quality
CH₄ + CO₂TRM-PGA process analyzer (rack / wall) · IR·OEM CO₂/CH₄ channel for skids
Industrial emissions · Dir. (EU) 2024/1785
permit monitoring · CEMS · QAL
CO₂ · CO · SO₂ · N₂OTRM-PGA multi-channel process analyzer · IR·OEM channels · GDC controller to SCADA
CBAM · ETS
verified actual emissions vs default values
CO₂TRM-PGA process analyzer + traceable calibration record · IR·OEM CO₂ channel
Buildings · EPBD 2024/1275
indoor-air-quality measuring & control devices
CO₂IR·OEM CO₂ channel for building-automation makers
Workplace safety · ATEX / OEL
toxic · combustible · O₂ in hazardous areas
multi-gasTRM-EX (E / CT / IR / SMC) · GDC alarm controller · GDC-S52 sampling · GASPOD cabinet
Catalogue

L1OEM NDIR channels — into your instrument

The sensing core with an interface contract. In-house 2-beam optics with reference channel and heated cell; calibration traceable to national primary gas standards. Delivered as OEM board or benched module, scoped to your gas, range and matrix.

L2Field instruments — install and connect

Complete transmitters and transducers with datasheet, manual and a per-unit calibration record — the number you defend in an audit.

L3Systems — collect, alarm, report

Controllers and cabinets that turn field readings into alarms, records and SCADA data — the layer that makes compliance repeatable.

Gas × technology

What each channel measures

One matrix, from our own datasheets: the measuring principle that serves each gas group and where it is typically used.

GasNDIR (IR)Thermocatalytic (CT)Electrochemical (E)Semiconductor (SMC)Typical use
CO₂
0–5000 ppm → 100 vol%
●···biomethane · CEMS · IAQ · CBAM
CH₄ · hydrocarbons
0–100 %LEL · vol%
●●··methane LDAR · biomethane · safety
SF₆
0–1000 / 0–2000 ppm · density
●··●F-gas · GIS / switchgear
Refrigerants R-134a · R-125 · R-22 · R-227ea · R-407c…
ppm ranges
●··●F-gas · leak detection
CO
0–300 / 500 / 1000 ppm
··●·safety · CEMS (E)
SO₂ · NO · NO₂ · N₂O
ppm ranges
··●·emissions · safety
O₂
0–25 vol%
··●·confined space · inerting
H₂S · NH₃ · HCN · Cl₂ · HF · HCl
ppm ranges
··●·toxic gas safety
H₂
0–500 / 1000 / 2000 ppm · %LEL
·●●·hydrogen · battery rooms
SiH₄ · AsH₃ · PH₃ · B₂H₆ · GeH₄ · WF₆ …
ppb–ppm
··●·semiconductor · GASPOD / GDC
Solvents · alcohols · aromatics (C₂–C₉)
%LEL
·●··process safety
Honest boundary. NDIR is our core and covers CO₂, CH₄/hydrocarbons, SF₆ and refrigerants. O₂, H₂, Cl₂ and H₂S have no usable IR absorption (or are masked by water) — those are served by the electrochemical, thermocatalytic and semiconductor channels of the TRM-EX. Full gas lists with ranges are in each datasheet.